Efficacy and safety of strong acid electrolyzed water for peritoneal lavage to prevent surgical site infection in patients with perforated appendicitis

Akihiro Yoneda, Akio Kubota, Gakuto Tani, Hisayoshi Kawahara, Katsuhisa Hirano, Makoto Yagi, Satoshi Umeda, Takeo Yonekura, Taro Goda, Tomohiro Ishii, Tomomitsu Tsuru, Yuko Tazuke

Read more:

DOI: 10.1007/s00595-014-1050-x DOI is the universal ID for this study.

This link will take you to the full study.

Abstract:

Purpose: Our previous experimental study of perforated peritonitis in rats proved that peritoneal lavage with strong acid electrolyzed water (SAEW) has no adverse effects, reduces the bacteria count in the ascitic fluid more effectively than saline, and increases the survival rate significantly. Thus, we conducted a randomized controlled study, applying SAEW in the treatment of perforated appendicitis in children.

Methods: Forty-four patients, aged 3-14 years, were randomly divided into two groups: Group S (n = 20), in which the peritoneal cavity was lavaged with 100 ml/kg saline and the wound was washed out with 200 ml saline; and Group E (n = 24), in which the peritoneal cavity was lavaged with 100 ml/kg SAEW and the wound was washed out with 200 ml SAEW.

Results: No adverse effect of SAEW was observed in Group E. There was no difference in the bacterial evanescence ratio of ascitic fluid after lavage between Groups S and E (11.1 and 15.8%, respectively). A residual abscess developed in one patient from each group (5.0 and 4.2%, respectively). The incidence of surgical site infection (SSI) was significantly lower in Group E than in Group S (0 and 20%, respectively; P < 0.05). There was no difference in the duration of pyrexia, positive C-reactive protein, leukocytosis, or hospital stay between the groups.

Conclusion: Peritoneal lavage and wound washing with SAEW have no adverse effects and are effective for preventing SSI.


Publish Year 2015
Country Japan
Rank Positive
Journal Surgery Today
Primary Topic Peritonium
Secondary TopicSurgery/Transplantation
Model Human
Tertiary TopicBacterial Infection
Vehicle Water (Electrolysis)
pH Acidic
Application Irrigation
Comparison
Complement